2x4 digits LCD display
Easy to use
9 level time intervals between 0-99.99s and 0-9999h
Selectable PNP or NPN sensor type
Selectable up/down counting direction
Adjustable minimum On and Off times for input signal
Memory option
12 different output modes
Adjustable display brightness
Parameter access protection on 3 levels
Easy installation and service operations with terminal plug-in connectors
RS-485 ModBus communication
CE marked according to European Norms
Environmental Conditions | |
Ambient/Storage Temperature | 0...50 ºC / -25...70 ºC |
Relative Humidity | 80% relative humidity for temperatures up to 31°C, decreasing linearly to 50% at 40°C |
Protection Degree | According to EN 60529 Front panel: IP65, Rear panel: IP20 |
Height | Max. 2000m |
Electrical Characteristics | |
Supply | 90-250V AC 50/60Hz or 10-30V DC / 8-24V AC |
Power Consumption | 5VA |
External Connections | Plug-in terminals |
Accuracy | ±0.01% ± 1ms |
Inputs | |
Start, Gate and Reset Input | Input types can be adjusted as PNP or NPN in programming mode Minimum On and Off times for input pulses can be adjusted between 1ms and 100ms For PNP input types, active level is 4V to 30V pulse For NPN input types, active level is 0V to 2V pulse |
Outputs | |
Control Output OUT1, OUT2 | OUT1: 250V AC, 2A (for resistive load), NO, NC-OUT2: 250V AC, 2A (for resistive load), NO |
SSR1, SSR2 Output | Open collector output(S.S. OUT): Max. 30V DC, 50mA |
Auxiliary Power Supply | 12V DC, max. 50mA (unregulated) |
Life Expectancy | Mechanical 5.000.000 operations (under no load), Electrical 200.000 operations (2A at 250V AC, resistive load) |
Housing | |
Mounting Method | Panel mounting |
Dimensions | W48xH48xD87 mm |
Weight | Approx. 230g (after packaging) |
Enclosure Material | Self extinguishing plastics |